Diabetes and obesity are complex conditions related to physiological imbalances. Researchers study many hormones to explore how pancreatic islet cell function, paracrine signaling, and energy homeostasis interplay in metabolic disorders. ALPCO’s portfolio of assays are optimized for range, sensitivity, sample type, and time. Leverage multiple formats – colorimetric or chemiluminescent ELISA, RIA – for manual or automated workflows.
Catalog #: 22-IG1MS-E01
Sensitivity: 0.315 ng/mL
Range: 0.5 - 18 ng/mL
Sample Types:
Citrate Plasma, EDTA Plasma, Heparin Plasma, Plasma, Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 22-LEPMS-E01
Sensitivity: 10 pg/mL
Range: 15 - 1600 pg/mL
Sample Types:
Citrate Plasma, EDTA Plasma, Heparin Plasma, Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 04-BI-20812
Sensitivity: 0.7 pmol/L
Range: 0 to 128 pmol/L
Sample Types:
Citrate Plasma, EDTA Plasma, Heparin Plasma, Plasma, Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 41-OPNHU-E01
Sensitivity: 0.05 ng/mL
Range: 0.31 - 20 ng/mL
Sample Types:
Heparin Plasma, Urine
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 04-BI-20403
Sensitivity: 1.4 pg/mL
Range: 25-400 pg/mL
Sample Types:
Citrate Plasma, EDTA Plasma, Heparin Plasma, Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 04-BI-20433
Sensitivity: 20 pmol/L
Range: 20-4000 pmol/L
Sample Types:
Citrate Plasma, EDTA Plasma, Heparin Plasma, Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 48-CINRT-E01
Sensitivity: 12.5 pg/mL
Range: 12.5 - 800 pg/mL
Sample Types:
EDTA Plasma, Heparin Plasma, Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 04-BI-20492
Sensitivity: 2.6 pM
Range: 15-240 pM
Sample Types:
EDTA Plasma, Heparin Plasma, Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 04-BI-20405
Sensitivity: LLOQ: 31 pmol/l
Range: 62.5-2,000 pmol/l
Sample Types:
Citrate Plasma, EDTA Plasma, Heparin Plasma
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 82-PINHUT-E01
Sensitivity: 0.5 pmol/L
Range: 10 - 250 pmol/L
Sample Types:
EDTA Plasma, Heparin Plasma, Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 04-BI-20409
Sensitivity: LLOQ: 0.09 nmol/l
Range: 0.37-12 nmol/l
Sample Types:
Citrate Plasma, EDTA Plasma, Heparin Plasma, Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 22-HGHHUU-E01
Sensitivity: 1.6 pg/mL
Range: 50 - 1000 pg/mL
Sample Types:
EDTA Plasma, Heparin Plasma, Plasma, Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric