GeneProof Molecular Diagnostics Assays & Instrumentation
Manual and automated sample-to-answer solutions for PCR-based molecular diagnostics offering universal protocols, simplified workflows, and a wide range of tests
The myCROBE Instrument is a fully automated sample-to-answer PCR solution covering the entire nucleic acid extraction and PCR process. Analyze up to 36 samples for up to 10 tests per sample with a maximum of 90 tests per run.
The croBEE System is a compact, fully automated system for nucleic acid extraction utilizing magnetic separation to generate high-quality DNA and RNA.
This piece includes a complete listing of PCR and RT-PCR kits for the detection and differentiation of bloodborne, neurological, respiratory, and sexually transmitted infections.
An overview of the myCROBE Instrument - a fully automated sample-to-answer PCR solution covering the entire nucleic acid extraction and PCR process.
An overview of the myCROBE Instrument - a fully automated sample-to-answer PCR solution covering the entire nucleic acid extraction and PCR process.
This flyer offers an overview of the gastrointestinal pathogen PCR / RT-PCR kits available from ALPCO.
Catalog #: 30-7828
Sensitivity: 0.05 µmol/L
Range: 0.1 - 2.0 µmol/L
Sample Types:
Citrate Plasma, EDTA Plasma, Plasma, Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 30-7860
Sensitivity: 0.1 µM
Range: 0.1 µM -2 µM
Sample Types:
EDTA Plasma, Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 30-KC-1700
Sensitivity: 0.02 µg/mL
Range: n/a
Sample Types:
Plasma, Serum, Whole Blood
Sample Size(s):
100 Tests
Catalog #: 30-KC-1700-NCC
Sensitivity: .02ug/mL
Sample Types:
Serum, Whole Blood
Catalog #: 30-KIF001
Sensitivity: 3 ng/L
Range: 3 - 15 ng/L
Sample Types:
Whole Blood
Sample Size(s):
96 Wells
Catalog #: 32-5118
Sensitivity: 0.8 pg/mL
Range: 1.95 - 250 pg/mL
Sample Types:
EDTA Plasma
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 32-5119
Sensitivity: 0.6 pg/mL
Range: 1.95 - 250 pg/mL
Sample Types:
EDTA Plasma
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 38-KIP1531
Sensitivity: 0.78 pg/ml
Range: 0.78 - 520 pg/ml
Sample Types:
EDTA Plasma
Sample Size(s):
100 Tubes
Detection:
I-125
Catalog #: 38-KIR1491
Sensitivity: 0.7 pg/ml
Range: 0.7 - 1500 pg/ml
Sample Types:
EDTA Plasma, Serum
Sample Size(s):
100 Tubes
Detection:
I-125
Catalog #: 43-FGFHU-E01
Sensitivity: 1.7 pg/mL
Range: 32.5 - 2000 pg/mL
Sample Types:
EDTA Plasma, Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 43-GP1HU-E01
Sensitivity: 0.05 pmol/L
Range: 0.64 - 48 pmol/L
Sample Types:
EDTA Plasma, Plasma
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 43-GPTHU-E01
Sensitivity: 0.6 pmol/L
Range: 2.1 - 54 pmol/L
Sample Types:
EDTA Plasma, Plasma
Sample Size(s):
96 Wells
Detection:
Colorimetric