GeneProof Molecular Diagnostics Assays & Instrumentation
Manual and automated sample-to-answer solutions for PCR-based molecular diagnostics offering universal protocols, simplified workflows, and a wide range of tests
The myCROBE Instrument is a fully automated sample-to-answer PCR solution covering the entire nucleic acid extraction and PCR process. Analyze up to 36 samples for up to 10 tests per sample with a maximum of 90 tests per run.
The croBEE System is a compact, fully automated system for nucleic acid extraction utilizing magnetic separation to generate high-quality DNA and RNA.
This piece includes a complete listing of PCR and RT-PCR kits for the detection and differentiation of bloodborne, neurological, respiratory, and sexually transmitted infections.
An overview of the myCROBE Instrument - a fully automated sample-to-answer PCR solution covering the entire nucleic acid extraction and PCR process.
An overview of the myCROBE Instrument - a fully automated sample-to-answer PCR solution covering the entire nucleic acid extraction and PCR process.
This flyer offers an overview of the gastrointestinal pathogen PCR / RT-PCR kits available from ALPCO.
Catalog #: 04-BI-20433MS
Sensitivity: LLOQ: 0.125 nmol/l
Range: 0.5-16 nmol/l
Sample Types:
Plasma, Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 04-BI-20742MR
Sensitivity: LLOQ: 0.5 nmol/l
Range: 1-32 nmol/l
Sample Types:
Plasma, Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 04-BI-20892
Sensitivity: 0.05 nmol/L
Range: 0.63 - 10 nmol/L
Sample Types:
Cell Culture, Plasma, Urine
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 04-BI-ANG2MR
Sensitivity: LLOQ: 21.9 pmol/l
Range: 43.7-1400 pmol/l
Sample Types:
Plasma, Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 04-BI-VAN1MR
Sensitivity: LLOQ: 6.25 pmol/l
Range: 6.25-200 pmol/l
Sample Types:
Plasma, Serum, Urine
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 17-HISRT-E01-RES
Sensitivity: 0.2 ng/mL
Range: 0.3 - 30 ng/mL
Sample Types:
EDTA Plasma
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 22-ADPMS-E01
Sensitivity: 0.008 ng/mL
Range: 0.025 - 1 ng/mL
Sample Types:
Cell Culture, Plasma, Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 22-ADPRT-E01
Sensitivity: 0.08 ng/mL
Range: 0.25 - 10 ng/mL
Sample Types:
Plasma, Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 22-BP2MS-E01
Sensitivity: 0.01 ng/mL
Range: 31.25 - 2000 pg/mL
Sample Types:
Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 22-BP3MS-E01
Sensitivity: 0.018 ng/mL
Range: 0.078 - 5.0 ng/mL
Sample Types:
Cell Culture, Plasma, Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 22-GHOMS-E01
Sensitivity: <0.04 ng/mL
Range: 0.04 - 45 ng/mL
Sample Types:
Plasma, Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric
Catalog #: 22-IG1MS-E01
Sensitivity: 0.315 ng/mL
Range: 0.5 - 18 ng/mL
Sample Types:
Citrate Plasma, EDTA Plasma, Heparin Plasma, Plasma, Serum
Sample Size(s):
96 Wells
Detection:
Colorimetric